SMD Sim.
Capa Simulation Result: FAIL - Bottleneck Detected
Model: SM-S938 | Avg Utilization: 86.6%
Processes
8
Bottlenecks
3
Avg Util.
86.6%
Peak Util.
138.9%
Process Utilization Overview
Print
86.8%
Chip-Mount
56.9%
Chip-Mount
59%
Shieldcan
104.2%
Test
125%
Underfill
69.4%
Tape
41.7%
TIM
97.3%
Router
138.9%
Detailed Capa Analysis
| Process | Equipment | Cycle (s) | Setup (min) | Capa/Hr | Required | Util. % | Gap | Status |
|---|---|---|---|---|---|---|---|---|
| DEK Horizon 03iX | 12.5 | 15 | 288 | 250 | 86.8% | +38 | OK | |
| Chip-Mount | Samsung SM482+ | 8.2 | 20 | 439 | 250 | 56.9% | +189 | OK |
| Chip-Mount | Samsung SM482+ | 8.5 | 20 | 424 | 250 | 59% | +174 | OK |
| Shieldcan | Custom Shield | 15 | 10 | 240 | 250 | 104.2% | -10 | Bottleneck |
| Test | ICT Tester V2 | 18 | 5 | 200 | 250 | 125% | -50 | Bottleneck |
| Underfill | Nordson EFD | 10 | 12 | 360 | 250 | 69.4% | +110 | OK |
| Tape | Auto Taping M1 | 6 | 8 | 600 | 250 | 41.7% | +350 | OK |
| TIM | Dispensing TIM | 14 | 10 | 257 | 250 | 97.3% | +7 | OK |
| Router | CNC Router V3 | 20 | 15 | 180 | 250 | 138.9% | -70 | Bottleneck |